Touch the end to the TLC plate and allow capillary action to draw the solution onto the plate. It is better to touch the spotter to the TLC 2–3 times for short amounts of time ( 1s) than to hold it against the plate for a longer time. The resulting spot should be 1–2 mm in diameter. Sketch a TLC plate, drawing a spot of Rf 0.4. Label the origin,solvent front and the spots. 100% (1 rating) Get this answer with Chegg Study. The TLC Tool is a drawing tool that allows you to easily depict Thin Layer Chromatography plates within a ChemDraw document. The tool creates a rectangular plate with. Usually, a thin layer chromatography plate is around 5–7 cm high, and a line is drawn around 0.5–1.0 cm from the bottom. That is the line in which you will spot your mixtures to separate. It is important that you spot the mixtures above the solvent level on your elution chamber! Use this action so that the drawing is activated and you can move it across the chart. Note that to do so, you can also select it with a Pointer (Active Tool) and drag-and-drop to a desired position. Once you activate a drawing, you can modify it by dragging-and-dropping its anchor points. Use this action to add the same drawing to. TLC Plate Editor Add-in for Accelrys Draw.

Introduction

Tlc plate drawing tool

Thin-layer chromatography (TLC) is a very commonly used technique in synthetic chemistry for identifying compounds, determining their purity and following the progress of a reaction. It also permits the optimization of the solvent system for a given separation problem. In comparison with column chromatography, it only requires small quantities of the compound (~ng) and is much faster as well.
Stationary Phase
As stationary phase, a special finely ground matrix (silica gel, alumina, or similar material) is coated on a glass plate, a metal or a plastic film as a thin layer (~0.25 mm). In addition a binder like gypsum is mixed into the stationary phase to make it stick better to the slide. In many cases, a fluorescent powder is mixed into the stationary phase to simplify the visualization later on (e.g. bright green when you expose it to 254 nm UV light).
Preparing the Plate
Do not touch the TLC plate on the side with the white surface. In order to obtain an imaginary start line, make two notches on each side of the TLC plate. You can also draw a thin line with pencil. Do not use pen. Why? The start line should be 0.5-1 cm from the bottom of the plate.


Capillary spotters

Place a melting point capillary and in the dark blue part of the Bunsen burner flame. Hold it there until it softens and starts to sag. Quickly remove the capillary from the flame and pull on both ends to about 2-3 times its original length. If you pull the capillary inside the flame, you will have a 'piece of art', but not a good spotter. Allow the capillary to cool down, and then break it in the middle. Make sure that you break off the closed end on one of them. Do not use gloves when you pull capillaries. You will have much better control without them!

Watch movie how to pull capillaries here here


Spotting the plate

The thin end of the spotter is placed in the dilute solution; the solution will rise up in the capillary (capillary forces). Touch the plate briefly at the start line. Allow the solvent to evaporate and spot at the same place again. This way you will get a concentrated and small spot. Try to avoid spotting too much material, because this will deteriorate the quality of the separation considerably (‘tailing'). The spots should be far enough away from the edges and from each other as well. If possible, you should spot the compound or mixture together with the starting materials and possible intermediates on the plate. They will serve as internal reference since every TLC plate is slightly different.


Developing a Plate
A TLC plate can be developed in a beaker or closed jar (see picture below). Place a small amount of solvent (= mobile phase) in the container. The solvent level has to be below the starting line of the TLC, otherwise the spots will dissolve away. The lower edge of the plate is then dipped in a solvent. The solvent (eluent) travels up the matrix by capillarity, moving the components of the samples at various rates because of their different degrees of interaction with the matrix (=stationary phase) and solubility in the developing solvent. Non-polar solvents will force non-polar compounds to the top of the plate, because the compounds dissolve well and do not interact with the polar stationary phase. Allow the solvent to travel up the plate until ~1 cm from the top. Take the plate out and mark the solvent front immediately. Do not allow the solvent to run over the edge of the plate. Next, let the solvent evaporate completely.

TLC chamber for development e.g. beacher
with a lid or a closed jar
after ~5 minafter ~10 min after drying
Tlc



Visualization

Reagent

Works well for

Colors

Notes

Iodine

Unsaturated and aromatic compounds

Brown spots

Not permanent

Sulfuric acid

General stain

Brown or black spots

Chromic acid

For difficult to stain compounds

Black spots

UV light

Compounds with extended conjugation like aromatic compounds

Pink on light green background

Only visible under UV light

Cerium sulfate

Good general stain, very well for alkaloids

Ferric chloride

Phenols

Purple

Ninhydrin

Amino acids, amines

Purple

2,4-Dinitrophenylhydrazine

Aldehydes, ketones

Yellow/orange

also called 'DNP'

Vanillin

Good general stain, very well for hydroxyl or carbonyl compounds

Colors vary

Potassium permanganate

Works well for all compounds that can be oxidized

Yellow on purple


Yellow or light brown on purple

at r.t. for alkenes and alkynes upon

heating for alcohols, amines, sulfides

Bromocresol Green

Carboxylic acids (pKa<5)

Yellow spot on blue background

Cerium molybdate (CAM, ‘Hanessian's Stain', Ceric staining)

Good general stain, very well with polyhydroxylated and carbonyl compounds

Blue or green spot

Upon heating, very sensitive!

p-Anisaldehyde

Good general stain, particularly sensitive towards nucleophiles

Varying colors on light pink plate upon heating

Does not work with alkenes, alkynes or aromatic system unless functional groups are present

Phosphomolybdic acid (PMA)

Very sensitive

Dark green spot on light green plate

Sensitivity can be enhanced by use of cobalt(II) chloride

Ehrlich's Reagent (Dimethylaminobenzaldehyde)

Indoles, amines

Pink or red-violet

Dragendorff-Munier Stain

Amines even the ones that are low in reactivity

Various colors


In either way, the spots on the TLC plate should be circled (marked) to have a permanent record how far the compound traveled on the plate. Asketch of the developed plate should be placed in your lab notebook. A picture (cell phone) could not hurt either.
Analysis
The components, visible as separated spots, are identified by comparing the distances they have traveled with those of the known reference materials. Measure the distance of the start line to the solvent front (=d). Then measure the distance of center of the spot to the start line (=a). Divide the distance the solvent moved by the distance the individual spot moved. The resulting ratio is called Rf-value. The value should be between 0.0 (spot did not moved from starting line) and 1.0 (spot moved with solvent front) and is unitless.
Plate

The Rf (=retardation factor) depends on the following parameters:

  • solvent system
  • absorbent (grain size, water content, thickness)
  • amount of material spotted
  • temperature

Tlc Plate Drawing Tool

Tlc Plate Drawing Tool

Thin-layer chromatography (TLC) is a very commonly used technique in synthetic chemistry for identifying compounds, determining their purity and following the progress of a reaction. It also permits the optimization of the solvent system for a given separation problem. In comparison with column chromatography, it only requires small quantities of the compound (~ng) and is much faster as well.
Stationary Phase
As stationary phase, a special finely ground matrix (silica gel, alumina, or similar material) is coated on a glass plate, a metal or a plastic film as a thin layer (~0.25 mm). In addition a binder like gypsum is mixed into the stationary phase to make it stick better to the slide. In many cases, a fluorescent powder is mixed into the stationary phase to simplify the visualization later on (e.g. bright green when you expose it to 254 nm UV light).
Preparing the Plate
Do not touch the TLC plate on the side with the white surface. In order to obtain an imaginary start line, make two notches on each side of the TLC plate. You can also draw a thin line with pencil. Do not use pen. Why? The start line should be 0.5-1 cm from the bottom of the plate.


Capillary spotters

Place a melting point capillary and in the dark blue part of the Bunsen burner flame. Hold it there until it softens and starts to sag. Quickly remove the capillary from the flame and pull on both ends to about 2-3 times its original length. If you pull the capillary inside the flame, you will have a 'piece of art', but not a good spotter. Allow the capillary to cool down, and then break it in the middle. Make sure that you break off the closed end on one of them. Do not use gloves when you pull capillaries. You will have much better control without them!

Watch movie how to pull capillaries here here


Spotting the plate

The thin end of the spotter is placed in the dilute solution; the solution will rise up in the capillary (capillary forces). Touch the plate briefly at the start line. Allow the solvent to evaporate and spot at the same place again. This way you will get a concentrated and small spot. Try to avoid spotting too much material, because this will deteriorate the quality of the separation considerably (‘tailing'). The spots should be far enough away from the edges and from each other as well. If possible, you should spot the compound or mixture together with the starting materials and possible intermediates on the plate. They will serve as internal reference since every TLC plate is slightly different.


Developing a Plate
A TLC plate can be developed in a beaker or closed jar (see picture below). Place a small amount of solvent (= mobile phase) in the container. The solvent level has to be below the starting line of the TLC, otherwise the spots will dissolve away. The lower edge of the plate is then dipped in a solvent. The solvent (eluent) travels up the matrix by capillarity, moving the components of the samples at various rates because of their different degrees of interaction with the matrix (=stationary phase) and solubility in the developing solvent. Non-polar solvents will force non-polar compounds to the top of the plate, because the compounds dissolve well and do not interact with the polar stationary phase. Allow the solvent to travel up the plate until ~1 cm from the top. Take the plate out and mark the solvent front immediately. Do not allow the solvent to run over the edge of the plate. Next, let the solvent evaporate completely.

TLC chamber for development e.g. beacher
with a lid or a closed jar
after ~5 minafter ~10 min after drying



Visualization

Reagent

Works well for

Colors

Notes

Iodine

Unsaturated and aromatic compounds

Brown spots

Not permanent

Sulfuric acid

General stain

Brown or black spots

Chromic acid

For difficult to stain compounds

Black spots

UV light

Compounds with extended conjugation like aromatic compounds

Pink on light green background

Only visible under UV light

Cerium sulfate

Good general stain, very well for alkaloids

Ferric chloride

Phenols

Purple

Ninhydrin

Amino acids, amines

Purple

2,4-Dinitrophenylhydrazine

Aldehydes, ketones

Yellow/orange

also called 'DNP'

Vanillin

Good general stain, very well for hydroxyl or carbonyl compounds

Colors vary

Potassium permanganate

Works well for all compounds that can be oxidized

Yellow on purple


Yellow or light brown on purple

at r.t. for alkenes and alkynes upon

heating for alcohols, amines, sulfides

Bromocresol Green

Carboxylic acids (pKa<5)

Yellow spot on blue background

Cerium molybdate (CAM, ‘Hanessian's Stain', Ceric staining)

Good general stain, very well with polyhydroxylated and carbonyl compounds

Blue or green spot

Upon heating, very sensitive!

p-Anisaldehyde

Good general stain, particularly sensitive towards nucleophiles

Varying colors on light pink plate upon heating

Does not work with alkenes, alkynes or aromatic system unless functional groups are present

Phosphomolybdic acid (PMA)

Very sensitive

Dark green spot on light green plate

Sensitivity can be enhanced by use of cobalt(II) chloride

Ehrlich's Reagent (Dimethylaminobenzaldehyde)

Indoles, amines

Pink or red-violet

Dragendorff-Munier Stain

Amines even the ones that are low in reactivity

Various colors


In either way, the spots on the TLC plate should be circled (marked) to have a permanent record how far the compound traveled on the plate. Asketch of the developed plate should be placed in your lab notebook. A picture (cell phone) could not hurt either.
Analysis
The components, visible as separated spots, are identified by comparing the distances they have traveled with those of the known reference materials. Measure the distance of the start line to the solvent front (=d). Then measure the distance of center of the spot to the start line (=a). Divide the distance the solvent moved by the distance the individual spot moved. The resulting ratio is called Rf-value. The value should be between 0.0 (spot did not moved from starting line) and 1.0 (spot moved with solvent front) and is unitless.

The Rf (=retardation factor) depends on the following parameters:

  • solvent system
  • absorbent (grain size, water content, thickness)
  • amount of material spotted
  • temperature

Tlc Plate Drawing Tool

Due to the fact that all those variables are difficult to keep constant, a reference compound is usually applied to the plate as well.

Tlc Plate Drawing Tool Free

Useful links

Tlc Plate Drawing Tool Download

Tlc Plate Drawing Tools

then...
Drag a border or corner. The number of lanes will not change.
Drag the origin or solvent front line.
Drag the origin tick to the new location.
1. Control-click in the plate.
NOTE: You can also delete lanes with the Eraser tool.
Drag the spot. The Rf displays as you drag.
Option+Drag the spot.
Click on the spot with the Eraser tool.
NOTE: If you erase all spots in a lane, the lane will be deleted.
1. Control-click on a spot.
NOTE: To display Rf for all spots, Control-click in the plate and select Show Rf from the TLC Spots submenu.
1. Control-click on a spot.
NOTE: To change the style for all spots, Control-click in the plate and choose the style from the TLC Spots submenu.
Shift+drag the spot. When you position the cursor on a spot and press 'Shift', the cursor assumes one of three shapes, depending on how it is positioned:
2. Horizontal arrow -used to widen a spot.
NOTE: You may want to zoom in to make positioning easier.




broken image